ACU(Automatic Control Unit) is equipment for maintaining broadcasting service by controlling error occurrence by observing and analyzing the status of digital broadcasting system.

Indoor-type broadcasting relay system is generally composed of 1 set of Exciter for falsification and demodulation and HPA(High Power Amplifier), BPF(Band Pass Filter) and dualized as 2 sets for reliability. ACU reports to control department after taking suitable action to service for normal status by checking the input, output and condition of each set.

ACU determines the errored set by referring the internal state and input/output generated from each set. Then it reports the action results to the control station after the services are normally processed through the appropriate measures.

< DTVR Broadcasting Relay System >
 
 


Operation Mode
  • Local - Manual/Auto
  • Remote - Manual/Auto
Control Function
  • TX ON & OFF
  • Fault reset
  • Auto change-over (Active Standby)
  • TX-A/B antenna selection
Monitoring and Display Function (Indication)
  • Receiving status (Normal/Abnormal) indication
  • Total fault
  • TX alarm
  • TX ON & OFF indication
  • Auto/Manual, Local/Remote
  • TX PS NORMAL
  • Auto change-over LED
  • TX-A/B antenna use
Alarm Function
  • Total fault
  • Exciter A/B fault
  • TR PA fault
  • TX output reflect fault
  • TR PA temperature fault
  • TX output low(80%) / high(120%) fault
  • PA power supply fault
TX Quality Monitoring Function
  • Output power/reflect power (uncertainty : 4% or less)
  • Transmission SNR


The Results of measurement is actual data drawn with RFA300A, and shows considerable improvement of distorted amplitude and status characteristic even on naked eyes.

Item Specifications Remarks
Equipment Shape 19inch Rack Type  
Height 3RU or less  
Depth 400mm or less  
Weight 5Kg or less  
LCD Panel and Key Function LCD Front arrangement
Signal Diagram KEY+LED Front arrangement
Control Key TX ON, TX OFF, RESET, EXCITER CHANGE,
AUTO, MANUAL, LOCAL, REMOTE
Front arrangement
Fault LED TOTAL, EXC-A, EXC-B, PA, P/S, VSWR Front arrangement
Exciter #1,#2 and Interface RS-232C (D-SUB 9Pin) Rear arrangement
HPA #1,#2 Interface RS-232C (D-SUB 9Pin) Rear arrangement
Switch Module Interface RS-232C (D-SUB 9Pin) Rear arrangement
PSU #1, #2 Interface RS-232C (D-SUB 9Pin) Rear arrangement
Power Monitor Interface RS-232C (D-SUB 9Pin) Rear arrangement
Communication with Upper Controller RS-485 (D-Sub 9Pin) Rear arrangement